Our company produce vertical turbine pump,vertical long axis pump, vertical type condensate pump ,vertical wet pit pump,right Angle gear box
Manufacturer of vertical turbine pumpFocus on vertical wet pit pump, right Angle gear box
HOTLINE:+8618507312158+8613974960765
Contact us
Vertical turbine pump manufacturers
HOTLINE::+8613974960765
Mobile:+8618507312158
Email:sale@ljpump.net
Address :China's hunan province changsha furong road long xiang industrial park
Your position: HOME >> Knowledge >> vertical turbine pump
vertical turbine pump

What are the causes of Vertical suspended Turbine Pumps packing leakage?

DATE:2021/7/24 10:46:24 Source:Vertical Turbine Pump Manufacturer and Vertical Suspension Pump Prices Provider Visits:

What are the causes of Vertical suspended Turbine Pumps packing leakage?


Packing deterioration is one of the main reasons for excessive water leakage and short service life of Vertical suspended Turbine Pumps packing. In addition, the causes of the failure include loss of elasticity and poor packing quality.


Among many fillers, asbestos filler is a kind of filler which is widely used at present. After drying and hardening, it will appear the phenomenon of hardening, which will greatly reduce the contact area with the Vertical suspended Turbine Pumps shaft and increase wear and tear. Here is the reason for leakage of Vertical suspended Turbine Pumps filler.


Long replacement period of filler, ageing of filler, poor quality of filler, loose structure, easy wear and failure are all the causes of water leakage of Vertical suspended Turbine Pumps filler, so it is necessary to replace the filler.


In addition, in the process of Vertical suspended Turbine Pumps operation, if the packing cap is too tight, the packing packs the Vertical suspended Turbine Pumps shaft so that the water of the water seal ring can not pass smoothly, which leads to the phenomenon that the filler fails due to overheating and hardening due to insufficient cooling and lubrication. At this time, the packing cap should be tightened until the water drops out.


The inner ring of Vertical suspended Turbine Pumps water seal ring is too small, the number of small holes on the ring is insufficient or blocked, the installation position of water seal ring is incorrect I water seal pipe is blocked, and the small gap between packing gland and Vertical suspended Turbine Pumps shaft is also the cause of water leakage of Vertical suspended Turbine Pumps packing.


Packing is an important part of the Vertical suspended Turbine Pumps, its normal operation and packing has a great relationship, so in the daily use of the process, we must often check.

Vertical suspended Turbine Pumps

Online Service
Contact

TEL

+8618507312158

+8613974960765

WeChat
Online
Service